Isokern DM double module chimneys: a buyer's guide

The Isokern DM is a complete system chimney made of volcanic pumice. Each course has two parts: an inner flue block that carries the flue gases and an outer casing that forms the chimney wall, with an air gap between them. Schiedel builds it this way so the flue stays hot while little heat reaches the outer casing, and so the inner and outer parts can move independently as they heat and cool. That reduces the risk of cracking, leaks and surface staining. The blocks are light enough for one person to lift, and the inner and outer parts are laid together with staggered joints.

DM chimneys can go inside or outside the building and suit masonry, timber frame and steel frame construction, in new builds and refurbishments. Schiedel rates the system for wood, solid fuel, oil and gas appliances. It is not suitable for condensing appliances, including biomass and pellet boilers or stoves.

DM36, DM44 or DM54: which size?

Pick the size by the flue diameter your appliance needs. Your appliance manufacturer's instructions give that figure. The three systems differ in casing size, flue size and the parts that finish the stack.

DM system sizes (Schiedel Isokern UK brochure, December 2024)

DM36DM44DM54
Flue internal diameter150mm180mm or 200mm (same casing)300mm or 345mm (same casing)
Typical use (Schiedel)Smaller output inserts, stoves and solid fuel or oil cookersInserts, stoves and small open firesMagnum firechests, larger appliances, inserts and open fires
Outer casing360mm square, 250mm high, 15kg440mm square, 300mm high, 30kg545mm square, 300mm high, 40kg
Capping for render490mm square570mm square670mm square
Capping for brickwork690mm square820mm square950mm square
Corbel for brickwork (75mm high)570mm square650mm square (offset and T corbels also made)800mm square
30° offset block86mm offset56mm or 86mm offset86mm offset

The DM is CE certified to EN 1858 (TÜV certificate 0036 CPR 90219 001). Its designations are T450 N1 D 3 G(00) and T600 N1 D 3 G(50). G(00) means zero distance to combustibles applies to straight chimneys with a ventilated terminal. Offset and non-ventilated chimneys need 38mm.

Installation and flue notes

  • Start on a suitable foundation and constructional hearth in line with the Building Regulations.
  • Bed the first outer casing on lip glue with its rebate (raised lip) uppermost, then glue the starter flue block inside it with the socket uppermost. Keep the air gap between flue block and casing clear all the way up.
  • Finished lip glue joints should be 2–3mm thick. Apply the glue in 12–15mm beads from the bag supplied.
  • Where a straight rendered chimney with a top ring passes through a floor or roof, zero distance to combustibles can apply, using a sliding joint of mineral wool or similar non-combustible material. Everywhere else, keep 38mm between the outside of the chimney and any structural timber. Floorboards, skirting boards and dado rails may touch the chimney.
  • Build the chimney straight wherever possible. Offset blocks must be glued and fully supported, with a starter flue block above them to keep the joints staggered.
  • Tie external chimneys to the building with two stainless steel wall ties at intervals of no more than 1.5m, and where the chimney leaves the roof.
  • Chimneys more than 1.4m above the roof line (1.1m where wind speeds exceed 44m/s) need high tensile steel reinforcement rods grouted into the casing holes.
  • For a stove in a recess, carry the support block on lintels or a cast concrete slab. Schiedel recommends at least 600mm of stove pipe before the support block, joined with a stainless steel adaptor sealed with fibre rope.
  • For a freestanding stove, fit a soot door casing and access flue block below the flue pipe entry and use the DM 45° flue entry kit. Keep any combustible insulation in the wall at least 1.5 times the pipe diameter away from the single wall flue pipe.
  • Inside the house, finish the casings with plasterboard on dabs or with plaster. The face against the wall needs no finish.

When the chimney is finished, it should be tested under Approved Document J, and a completed chimney notice plate fixed in the home. Leave it for at least 72 hours before use, then light only small fires for the first week.

Isokern DM: frequently asked questions

Can an Isokern DM chimney touch timber?

Only in one case. A straight rendered DM chimney with a ventilated top ring can have zero distance to combustibles where it passes through a floor or roof. Offset and non-ventilated chimneys need 38mm clearance from structural timber. Non-structural items such as floorboards and skirting may touch the chimney.

Do I need a corbel?

Only if the chimney will be clad in brick or stone above the roof. The corbel is fitted just below the roof to carry the brickwork. A rendered stack is finished with a capping for render instead.

Does a tall chimney need reinforcing?

Yes. Above 1.4m over the roof line, or 1.1m in areas where wind speeds exceed 44m/s, Schiedel requires steel reinforcement rods grouted into the casings. Start the rods at least as far below the roof as the chimney rises above it.

Can I use a DM chimney with a pellet stove?

No. Schiedel states the pumice systems are not suitable for condensing appliances, including biomass and pellets.

How do I work out which blocks to order?

Use our DM Calculator, which picks the casings, flue blocks and accessories for your chimney height. For a brick stack you will also need the corbel and capping for brickwork in your DM size.

Where to start:DM Calculator · DM36 chimney system pack for render · DM54 6 metre flue pack for brickwork · DM36 corbel · DM44 corbel · DM54 corbel · Lip glue · Magnum firechests


Stovesaver Blog

Chesneys Mk3 Wood Burning Stoves in New Builds: Compliance, SAP Boosts, and Cost-Saving Strategies


on
In the world of new build homes, where every decis...

Isokern Pumice Liners: The Gold Standard for Safe, Efficient Chimneys

Exploring Isokern’s Range of Gathers and Firechests for Superior Chimney Solutions