Code ICID-WE-125-BA
Ex VAT £1,472.99Inc VAT £1,767.59
Official Schiedel install diagram: rear outlet twin-wall (generic system illustration — not exact diameter/finish)
Code ICID-WE-125-BA
Ex VAT £1,472.99Inc VAT £1,767.59
Save
Earn 0 reward points with this product.

Sorry we're out of stock!

Enter your email address below and we’ll notify you as soon as it becomes available.

  • Description

    This Schiedel ICID Plus pack is for taking a wood-burning or multi-fuel stove flue out through an external wall, then up the outside of the house. It is a component pack for a typical wall-exit layout — not a one-size-fits-all complete chimney for every property.

    Diameter and finish: 125 mm internal flue diameter, stainless steel outer case.

    What is included

    • 1 × insulated appliance connector (pushes into the stove outlet and starts the twin-wall system)
    • 1 × short twin-wall pipe (about 160 mm)
    • 1 × masonry wall sleeve (for the opening through a solid wall)
    • 2 × trim collars (neat finish each side of the wall)
    • 1 × 135° tee with drain (turns the flue upward outside and allows condensate drainage)
    • 1 × tee cap
    • Twin-wall pipe lengths for an illustrative external rise (1 × about 750 mm, 4 × about 960 mm, 1 × about 293 mm)
    • 1 × adjustable pipe (about 215–310 mm) to fine-tune the height
    • 3 × standard wall bands and 2 × extended wall-band brackets (to support the external run)
    • 1 × raincap with bird mesh
    • 12 × locking bands (secure each twin-wall joint)

    What is not included

    • Extra pipe if your house needs a taller stack than this illustrative rise
    • High-temperature paint (Schiedel requires a high-temperature finish on parts within about 600 mm of the stove)
    • Parts for timber-frame or non-masonry walls beyond the masonry sleeve supplied
    • A different terminal (for example without mesh), flat-roof flashings, or structural design
    • Confirmation that this diameter suits your particular stove — always follow the stove maker’s flue size

    Please note: Installation must comply with Building Regulations and Schiedel’s ICID Plus instructions, and should be carried out by a competent person (for solid fuel in England and Wales this is typically a HETAS-registered installer, or approved by Building Control). Clearances to combustible materials, wall-band spacing and structural loads must follow the manufacturer’s instructions. This pack does not guarantee suitability for every stove or every building.

  • Reviews (0)

    Be the first to review this product.


    Leave your own review

Send this to a friend

Complete the form below and we’ll send the product details to a friend


Stovesaver Blog

Chesneys Mk3 Wood Burning Stoves in New Builds: Compliance, SAP Boosts, and Cost-Saving Strategies


on
In the world of new build homes, where every decision impacts energy efficiency, complianc...

Isokern Pumice Liners: The Gold Standard for Safe, Efficient Chimneys

Exploring Isokern’s Range of Gathers and Firechests for Superior Chimney Solutions