Isokern Pumice Liner Packs

Schiedel Isokern Pumice Chimney Liners are designed to be built into your chimney stack normally under new house construction aswell as relining existing masonry chimneys. These Liners are made from high insulative Pumice which helps with your chimneys performance and efficiency.

Showing 1 - 9 of 18 items

These liners come in a variety of sizes from 150mm,  which is ideal for many wood or multi fuel stoves,  up to 600mm internal diameter for specialist flue such as large open fires. Isokern also offer stainless steel connections to enable you to go from stainless steel flue pipe to Pumice liner giving a proper connection for the best installations

PDFIsokern Pumice Brochure

Isokern pumice liner packs: a buyer's guide

A liner pack gives you everything for one straight run of Isokern pumice flue in a single order, at a set height: 4.8, 6.0, 7.2 or 9.0 metres. Each pack contains rebated 600mm pumice liners, lip glue for the joints, bags of light expanded clay aggregate to insulate around the liners, and a chimney notice plate. Most packs for stove connections also include the liner support block and stainless steel adaptor that join the liner run to the stove pipe. Check the list on each pack, because the exact parts vary by diameter.

Schiedel designs pumice liners for masonry chimneys, with the liners surrounded by brick, block or stone. They work for a new-build chimney or for relining an existing one, with inserts, stoves, open fires and cookers burning wood, solid fuel, oil or gas. They are not suitable for condensing appliances, including pellet or biomass.

Choosing the diameter and height

Start with the flue size in your appliance manufacturer's instructions, then measure the height from the support point to the top of the stack. If your run falls between pack heights, add individual liners to the nearest pack below. Our Liner Calculator picks the parts for your height.

Liner sizes used in our packs (Schiedel Isokern UK brochure, December 2024)

Liner internal diameterOutside diameterWeight per 600mm linerSupport plate
150mm200mm8kg340mm square (210mm opening)
175mm235mm11kg360mm square (255mm opening)
200mm250mm12kg360mm square (255mm opening)
225mm285mm14kg–
350mm416mm27kg–

The 150mm to 225mm packs come in 4.8, 6.0, 7.2 and 9.0 metre lengths. The 350mm pack is 7.2 metres.

Installation and flue notes

  • Build on a suitable foundation and constructional hearth in line with the Building Regulations.
  • For a stove in a recess, fit lintels above the recess with the support plate under the support block, or cast a concrete slab lintel. Bed the support block in a weak mortar mix. Schiedel recommends at least 600mm of stove pipe before the chimney connection.
  • Install the liners socket uppermost and seal each joint with lip glue. The finished joints should be 2–3mm thick.
  • Clad the liners with at least 100mm of brickwork or medium density (7kN) blockwork, with at least 15mm of clay aggregate insulation between liner and masonry. Mix 20 parts aggregate to 1 part cement with a little water.
  • For bends, support them properly and backfill with the aggregate mix. Schiedel allows at most two offsets (four bends) per chimney, no more than 45° from vertical. Cut joints need a steel collar as well as lip glue.
  • Keep combustible materials 200mm from the inside of the liner or 40mm from the outside of the masonry. Floorboards, skirting, dado and picture rails, mantel shelves and architraves are the exceptions.
  • Dress the lead tray up the outside of the liners, and leave weep holes above it. Finish the top with 1:3 cement and sharp sand flaunching around the liner or a chimney pot, at a height that meets Approved Document J.
  • After completion, test the chimney under Approved Document J and fix the notice plate, ideally near the consumer unit.

Isokern liner packs: frequently asked questions

Can I reline an existing chimney with an Isokern pack?

Yes. Schiedel designs pumice liners for relining existing masonry chimneys as well as for new builds. The liners must be surrounded by the masonry and insulated with clay aggregate.

How much clay aggregate do I need?

It depends on the size of the void inside your chimney. Each pack lists the quantity for a stated internal chimney size. Larger voids need more bags, which you can add from the accessories range.

Can the liner run have bends?

Yes, up to two offsets (four bends) per chimney, each no more than 45° from vertical. Bends need support and backfill, and any cut joint needs a steel collar and lip glue.

Are pumice liners suitable for a pellet stove?

No. Schiedel states pumice liners are not suitable for condensing appliances, including pellet or biomass.

When can I light the fire?

Leave the chimney at least 72 hours after installation. Then burn only small fires for the first week and build up gradually.

How should the flue be swept?

At least twice a year, before and after the heating season, with a medium density polypropylene brush the same diameter as the flue. Never use a steel brush on pumice.

Popular packs:150mm 4.8m · 150mm 7.2m · 175mm 6.0m · 200mm 6.0m · 225mm 6.0m. Need single items? See Isokern liners and accessories.


Stovesaver Blog

Chesneys Mk3 Wood Burning Stoves in New Builds: Compliance, SAP Boosts, and Cost-Saving Strategies


on
In the world of new build homes, where every decis...

Isokern Pumice Liners: The Gold Standard for Safe, Efficient Chimneys

Exploring Isokern’s Range of Gathers and Firechests for Superior Chimney Solutions